Our Ask An Expert knowledge base contains answers to questions from designers like you. Browse the knowledge base by category or search key words. Not seeing what you need? Ask An Expert a question of your own.
For MURS360T3 75A non repititive current is given for 60Hz,thats 16mA. I want to know how much will be the current for 112 ms . This is the pulse which we apply in our circuit .Is there any graph you can provide us relating to Ifsm?
The only available value of IFSM for the MURS360 is shown in Figure 11, Page 5 of our Surface Mount Ultrafast Power Rectifiers Data Sheet. Unfortunately, we do not specify IFSM for square wave pulse duration longer than 10ms.
Answered by: ON Semiconductor
2013-04-25 14:31:47.09