Psi J-Case-top ~ 30°C/W
The best we can do in this situation is to use Psi J-Case-top to characterize the application.
Power up the circuit wait for 10 minutes then make a case temperature measurement.
Then calculate the junction temperature.
Tj=Tcase + Psi J-Case-top*Pd
Thank you.